Thermal Conductivity Values of Rockwool Products, λ ( W/mK)

Building products

The thermal conductivity (λ value) of Rockwool products at a mean temperature of 10°C is in the range of 0.034 to 0.044 W/mK. The thermal resistance (R value) of a specific product can be found by dividing its thickness in metres by the λ value.

 0.034 W/mK 0.035 W/mK 0.036 W/mK 0.037 W/mK 0.038 W/mK
. RW3
. RW5
. HP Partial Fill
 (40-90mm)
. Rainscreen
  DuoSlab
  (50&75mm)
. Rockliner Slab
. Firebatt 2000*

. Flexi Slab
  (140mm)

. RWA45
. RW6
. Rockfall U/lay
. Rainscreen
  DuoSlab
  (100-150mm)
. HP Partial Fill
  (100mm)
. Rockclose
. RockReveal
. Rockshield Slab
. BeamClad
. Fire Barrier

. Cavity Slab
. Acoustic 
  Partition Slab

. Flexi Slab
  (50-120mm)
. DuoRock
. Rockfloor 
  (Thermal)
. Rockfall O/lay
 0.039 W/mK  0.040 W/mK 0.042 W/mK 0.043 W/mK 0.044 W/mK
. EnergySaver
. Hardrock DD
. Cladding Roll
. Acoutic Infill
Rockfloor   (Acoustic)
. Slimfloor
  base slab
. Rockshield  Lamella
. Conrock 10*

 . Conrock 12.5*. Blown Loft*. Roll
. Rollbatt

































* Lambda values 90/90 is lambda 10
Thermal Resistance, R (m2K/W)=Thickness (mm)/(1000 x λ (W/mK))

Industrial products
The thermal conductivity (λ value) of Rockwool products at a mean temperature of 10°C is in the range of 0.034 to 0.044 W/mK. The thermal resistance (R value) of a specific product can be found by dividing its thickness in metres by the λ value.

                                                           Mean Temperature (ºC)
50ºC100ºC150ºC200ºC250ºC300ºC350ºC400ºC

 Slabs

RWA450.0400.0500.0630.080    
RW30.0390.0470.0580.0700.085   
RW50.0370.0440.0540.0640.0750.0880.1040.122
RW60.0370.0440.0510.0600.0700.0810.0930.106

 Industrial

Process Pipe Sections0.0370.0440.0510.0600.0700.0810.0930.106
Pipe Section Mat0.0370.0440.0510.0600.0700.0810.0930.106
Industrial Wired Mat0.0380.0440.0540.0650.0770.0910.107 
H.D. Wired Mat0.0370.0440.0520.0610.0710.0820.0960.109

 HVAC

        
H & V Pipe Sections0.0370.0440.0520.0610.0710.0820.0960.109
Ductwrap/Ductslab0.0400.0500.0630.080    
Lamella mat0.0430.0540.0690.092

 Marine

        
Firebatt 8250.0370.0440.0530.0620.0730.0860.1000.116

 