Building elements |
Construction guides |
Performance |
NBS Plus clause |
CAD downloads |
Partition walls, timber stud - new build |
Method
 |
Acoustic E2-Rw 40dB
Fire resistance approx. 30min |
P10-230 |
DXF DWG DWF |
|
Partition walls, twin timber frame |
Method
 |
Acoustic E2-Rw 46dB
Fire resistance 60min |
P10-230 |
|
|
Partition walls, 70 mm metal stud - new build |
Method
Movie
 |
Acoustic E2 & E4- Rw 57dB
Fire resistance 90min |
K10-115 K10-125 |
Isometric view DXF DWG DWF
Plan view DXF DWG DWF |
|
Partition walls, timber frame 146 mm metal stud - new build |
Method
 |
Acoustic E2 & E4- Rw 53dB
Fire resistance 60min |
K10-115 K10-125 |
|
|
Separating walls, twin timber frame - new build |
Method
 |
Acoustic E1-DnTw+Ctr
45dB (or greater)
Fire resistance min. 60min |
K10-115 K10-125 |
|
|
Separating walls, timber frame - Material change of use |
Method
 |
Acoustic E1-DnTw+Ctr
43dB (or greater)
|
K10-115 K10-125 |
|
|
Separating walls, twin timber frame without sheathing board - new build |
Method
Movie
 |
Acoustic & Fire Robust details- E-WT-1 |
P10-230 |
Isometric view DXF DWG DWF
Plan view DXF DWG DWF |
|
Separating walls, twin timber frame with sheathing board - new build |
Method
 |
Acoustic & Fire Robust details- E-WT-2 |
P10-230 |
|
|
Separating walls, twin metal frame - new build |
Method
Movie
 |
Acoustic & Fire Robust details- E-WS-1 |
P10-230 |
Isometric view DXF DWG DWF
Plan view DXF DWG DWF |
|
Separating floors, precast concrete - new build | Method
Movie
 | Acoustic E1-Airborne: DnTw+Ctr
45dB (or greater) Impact: 62dB LnTw (or less)
Fire resistance min. 60min | M10-290 M13-260
| DXF DWG DWF
| |
Separating floors, concrete/ beam & block - new build | Method
Movie
 | Acoustic E1-(65mm sand & cement screed) Airborne: DnTw+Ctr=57dB
Impact: 43dB LnTw
(40mm proprietary screed) Airborne: DnTw+Ctr=61dB
Impact:45dB LnTw
Fire resistance min. 60min | M10-290 M13-260
| DXF DWG DWF
| |
Separating timber batten raft floors - new build |
Method
 |
Acoustic E1- Airborne: Rw 49dB Impact: 55 dB Lnw
Fire resistance min. 60min |
K20-150 K20-160
|
|
|
Separating floors, timber - new build | Method
Movie
 | Acoustic E1-Airborne: Rw 54 dB Impact: Lnw 62dB
Fire resistance min. 60min
| K11-215 K11-225 K11-235 K11-245 | DXF DWG DWF
| |
Separating floors, metal - new build | Method
Movie
| Acoustic | K11-215 K11-225 K11-235 K11-245 | DXF DWG DWF
| |
Separating floors, timber platform with independent ceiling treatment - new build | Method
 | Acoustic E1-Airborne: DnTw+Ctr
45dB (or greater) Impact: 62dB LnTw(or less)
Fire resistance min. 60min | K11-215 K11-225 K11-235 K11-245 | | |
Separating floors, timber platform with independent ceiling treatment - Material change of use
|
Method
 |
Acoustic E1-Airborne: DnTw+Ctr
43dB (or greater) Impact: 64dB LnTw(or less)
|
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, timber platform floor with recessed downlighters - new build | Method
 | Acoustic E1-Airborne: Rw 53dB Impact: 54dB Lnw
Fire resistance min. 60min | K11-215 K11-225 K11-235 K11-245 | | |
Separating floors, timber platform with absorbent material - Material change of use
| Method
 | Acoustic E1-Airborne: DnTw+Ctr
43dB (or greater) Impact: 64dB LnTw(or less)
| K11-215 K11-225 K11-235 K11-245 | | |
Separating floors, timber platform floor - Material change of use & refurbishment | Method
 | Acoustic E4-Airborne: Rw 59dB Impact: 57dB Lnw
E1-Airborne: Rw 48 dB (Rw 59 - 11 Ctr)
Impact: Lnw 57 dB
Fire resistance min. 60min
| K11-215 K11-225 K11-235 K11-245 | | |
Separating floors, timber platform floor - refurbishment | Method
 | Acoustic E4-Airborne: Rw 66dB Impact: 54dB Lnw
Fire resistance min. 60min | K11-215 K11-225 K11-235 K11-245 | | |
Separating / Intermediate timber floors - refurbishment |
Method
Method
 |
Acoustic E2- Rw 40dB
Fire resistance min. 60min
|
P10-240 |
|
|
Intermediate timber batten raft floors -refurbishment |
Method
 |
Acoustic E4-Airborne: Rw 62dB Impact: 55 dB Lnw
|
K20-150 K20-160 |
|
|
Exposed intermediate floor soffits, concrete deck |
Method |
Acoustic, thermal, fire |
K10-215 K10-225 K10-235 |
DXF DWG DWF |
|
Stair treatment - Material change of use
|
Method  |
Acoustic
E1-Airborne: DnTw+Ctr
43dB (or greater)
Impact: 64dB LnTw(or less)
|
P10-240 |
DXF DWG DWF |
|
Download free DWG from Autodesk & Adobe Reader
 |
|
|
| Back
| |
|
| |
|
Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |
|
Copyright © Rockwool Limited, Disclaimer |
|
|
|