Rockwool Flexi - U Values
Cold timber frame - external cavity wall
Prescribed U Value W/m2K
(England and Wales) Extensions: 0.30 Renovation & Repair work: 0.35 New build requirement could range between 0.28 and 0.25
(Republic of Ireland) 0.27
(Scotland, with boiler SEDBUK ) 0.30
U Values (W/m2K)
Timber frame cavity wall, standard construction, insulation fully filling studs. Internal finishes: (a) 1 layer plasterboard (b) 2 layers plasterboard
| Standard Breather Membrane | | Tyvek 'Reflex' Breather Membrane | | | Internal finish | a | b | a | b | Thickness mm | | | | | | 90 | 0.41 | 0.40 | 0.36 | 0.35 | | 100 | 0.38 | 0.37 | 0.33 | 0.33 | | 120 | 0.33 | 0.32 | 0.29 | 0.29 | | 140 | 0.28 | 0.27 | 0.25 | 0.25 |
|
|
|
| Back
| |
|
| |
|
Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |
|
Copyright © Rockwool Limited, Disclaimer |
|
|
|