Building elements |
Construction guides |
Performance |
NBS Plus clause |
CAD downloads |
Separating floors, dense concrete - new build |
Method
Movie
 |
Acoustic E1-Airborne: DnTw+Ctr
above 45dB Impact: less than 62dB LnTw
|
M10-290 M13-260 K11-215 K11-225 K11-235 K11-245 K11-275 K11-295 K20-150 K20-160 |
DXF DWG DWF |
|
Separating floors, concrete in-situ - new build |
Method
 |
Acoustic Robust details E-FC-2 |
M10-290 M13-260 K11-215 K11-225 K11-235 K11-245 K11-275 K11-295 K20-150 K20-160 |
|
|
Separating floors, steel concrete composite - new build |
Method
 |
Acoustic Robust details E-FS-1
|
M10-290 M13-260 K11-215 K11-225 K11-235 K11-245 K11-275 K11-295 K20-150 K20-160 |
|
|
Separating floors, precast concrete - new build |
Method
Movie
 |
Acoustic E1-Airborne: DnTw+Ctr
45dB (or greater) Impact: 62dB LnTw (or less)
Fire resistance min. 60min |
M10-290 M13-260
|
DXF DWG DWF
|
|
Separating floors, concrete/ beam & block - new build |
Method
Movie
 |
Acoustic E1-(65mm sand & cement screed) Airborne: DnTw+Ctr=57dB
Impact: 43dB LnTw
(40mm proprietary screed) Airborne: DnTw+Ctr=61dB
Impact:45dB LnTw
Fire resistance min. 60min |
M10-290 M13-260
|
DXF DWG DWF
|
|
Separating floors, precast concrete - new build |
Method
 |
Acoustic Robust details E-FC-3
|
M10-290 M13-260 K11-215 K11-225 K11-235 K11-245 K11-275 K11-295 K20-150 K20-160 |
|
|
Separating floors, timber - new build |
Method
Movie
 |
Acoustic E1-Airborne: Rw 54 dB Impact: Lnw 62dB
Fire resistance min. 60min
|
K11-215 K11-225 K11-235 K11-245 |
DXF DWG DWF
|
|
Separating floors, timber platform with independent ceiling treatment - new build |
Method
 |
Acoustic E1-Airborne: DnTw+Ctr
45dB (or greater) Impact: 62dB LnTw(or less)
Fire resistance min. 60min |
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, timber platform floor with recessed downlighters - new build |
Method
 |
Acoustic E1-Airborne: Rw 53dB Impact: 54dB Lnw
Fire resistance min. 60min |
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, timber platform with absorbent material - Material change of use
|
Method
 |
Acoustic E1-Airborne: DnTw+Ctr
43dB (or greater) Impact: 64dB LnTw(or less)
|
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, timber platform floor - Material change of use & refurbishment |
Method
 |
Acoustic E4-Airborne: Rw 59dB Impact: 57dB Lnw
E1-Airborne: Rw 48 dB (Rw 59 - 11 Ctr)
Impact: Lnw 57 dB
Fire resistance min. 60min
|
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, timber platform floor - refurbishment |
Method
 |
Acoustic E4-Airborne: Rw 66dB Impact: 54dB Lnw
Fire resistance min. 60min |
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, precast concrete |
Method
 |
Acoustic E4-Airborne: Rw 57dB Impact: 53dB Lnw
Fire resistance min. 60min
|
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, precast concrete |
Method
 |
Acoustic E4-Airborne: Rw 59dB Impact: 50dB Lnw
Fire resistance min. 60min
|
K11-215 K11-225 K11-235 K11-245 |
|
|
Separating floors, metal - new build |
Method
Movie
|
Acoustic |
K11-215 K11-225 K11-235 K11-245 |
DXF DWG DWF
|
|
Download free DWG from Autodesk & Adobe Reader
 |
|
|
| Back
| |
|
| |
|
Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |
|
Copyright © Rockwool Limited, Disclaimer |
|
|
|