Rockfloor U Values
Below concrete ground bearing slab

Prescribed U Value W/m2K

 England, Wales, Extensions: 0.22
Renovation & Repair work: 0.25
New build requirement could range between 0.20 and 0.18

Republic of Ireland and
 Scotland (with boiler SEDBUK) 0.25

Because the U value for ground floors is dependent upon
size, shape, soil type perimeter edge insulation etc., it is not
possible to quote specific values. The following tables show
insulation thickness required to suit floor areas shown.

Note: Rockfloor should be laid in accordance with BS 8204: Part 1.




 Product Rockfloor
U value
 0.25 W/m2K 0.22 W/m2K0.20 W/m2 0.18 W/m2K
Exposed Perimeter
(P/A)
 Rockfloor
mm
 Thickness
mm
Thickness
mm 
 Thickness
mm
 0.1 nilnil nil nil 
 0.2 30 50 6585 
 0.3 60 80 95 115
 0.4 75 95 110 130
 0.5 85 105 120 140
 0.6 90 110 130 150
 0.7 95 115 130 150
 0.8 105 120 140 160
 0.9 105 125 140 160
 1.0 110 130 145 165

 
Rockwool Rockfloor can be installed below the concrete slab or below screed.


 