Rockfloor U Values Block & beam suspended floor
Prescribed U Value W/m2K
England, Wales, Extensions: 0.22 Renovation & Repair work: 0.25 New build requirement could range between 0.20 and 0.18
Republic of Ireland and Scotland (with boiler SEDBUK) 0.25
Because the U value for ground floors is dependent upon size, shape, soil type perimeter edge insulation etc., it is not possible to quote specific values. The following tables show insulation thickness required to suit floor areas shown. Note: Rockfloor should be laid in accordance with BS 8204: Part 1.
Product Rockfloor U value | 0.25 W/m2K | 0.22 W/m2K | 0.20 W/m2K | 0.18 W/m2K | Exposed Perimeter (P/A) | Rockfloor mm | Thickness mm | Thickness mm | Thickness mm | | 0.1 | nil | 30 | 50 | 65 | | 0.2 | 65 | 80 | 100 | 120 | | 0.3 | 80 | 100 | 120 | 140 | | 0.4 | 95 | 115 | 130 | 150 | | 0.5 | 100 | 120 | 135 | 160 | | 0.6 | 105 | 125 | 140 | 160 | | 0.7 | 105 | 130 | 145 | 165 | | 0.8 | 110 | 130 | 145 | 165 | | 0.9 | 115 | 130 | 150 | 170 | | 1.0 | 115 | 135 | 150 | 170 | Rockwool Rockfloor is laid over the dense beam and block floor below screed or t&g flooring grade chipboard where floor heights are limited.
|
|
|