Rockwool Roll & Rollbatt U Values
Pitched roof - between & over joists
Prescribed U Value W/m2K
(England and Wales - Part L 2006) 0.16 extensions, renovation & repair work, New build requirement could range between 0.13 and 0.12 (Republic of Ireland-Technical Guidance Document 2006 edition) 0.16
(Scotland, with boiler SEDBUK-Part J) 0.16
Ceiling joist
| 38x100mm
| | 47x100mm
| | | Joist spacing | 400mm | 600mm | 400mm | 600mm
| Insulation Thickness mm | U Values W/m2K
| U Values W/m2K | U Values W/m2K | U Values W/m2K | | 100 | 0.22 | 0.21 | 0.22 | 0.21 | | 150 | 0.17 | 0.17 | 0.17 | 0.17 | | 170 | 0.16 | 0.16 | 0.16 | 0.16 | | 200 (100+100) | 0.15 | 0.14 | 0.15 | 0.14 | | 250 (100+150) | 0.12 | 0.12 | 0.13 | 0.12 | | 300 (150+150) | 0.11 | 0.11 | 0.11 | 0.11 |
Construction: 100mm Rockwool Roll between joists (with the additional thickness of Rockwool Roll laid over joists).
|