| Installing Acoustic Membrane |
Standing Seam Systems
For built up metal roofing system applications (e.g. standing seam), Rockwool Acoustic Membrane should be applied between the metal outer sheet and insulation.
For enhanced performance, the membrane should also be positioned between the insulation layers.
A typical construction;
. Aluminium outer sheet . Rockwool Acoustic Membrane 5 (5kg/m2) – 1 layer . Rockwool Cladding Roll . Rockwool Acoustic Membrane 5 (5kg/m2) – 2 layers . Rockwool RW3 Slab . Vapour Control Layer . Steel liner tray
In the absence of test data, Rockwool Limited have assessed that similar constructions with combinations of Rockwool Acoustic Membrane and Rockwool insulation materials are likely to achieve Weighted Sound Reduction Index values of up to 50 dB. For installation of the Standing Seam system please contact the manufacturer
|
|
|
| Back
| |
|
| |
|
Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |
|