SEPARATING & INTERNAL FLOOR  SOLUTIONS
Separating Floors

When  insulating internal floors, it is important to ensure that the building meets with the appropriate Building Regulation requirements.
 
By adopting the Rockwool SoundPro solutions specifiers can meet and exceed the required ADE standards for Internal floors.


Intermediate Floors (within the same dwelling)

The Approved Document E 2003 Edition – Resistance to the passage of sound, introduced standards for internal floors in dwelling houses, flats and rooms for residential purposes. By adopting the Rockwool SoundPro solutions you can meet and exceed the required ADE standards for Internal and Separating floors.
 
The new Approved Document E (2003 edition) introduces, for the first time, performance criteria for Internal floors within the same building and dwelling (E2).This is based on laboratory rating (Rw) for which a minimum value for airborne sound insulation of Rw 40dB is required. Installing Rockwool Flexi slab between timber or metal floor  joists can meet this performance requirement.

 

Separating Floors 
Concrete 
Rockfloor 
(Acoustic)

Slimfloor  
(Acoustic)

Rockwool Flexi +
Rockfloor

(Acoustic)

Timber joists
Rockwool Flexi +
Rockfloor

(Acoustic)

Metal joists

Rockwool Flexi +
Rockfloor

(Acoustic)


Intermediate Floors
Timber & metal joists
Rockwool Flexi
(Acoustic)


Exposed Intermediate
Floors/Soffits
Concrete
Rigid slab RW5-tissue faced
(Thermal, Acoustic, Fire)

Rockwool Flexi
(Thermal, Acoustic, Fire)



A Separating floor is defined as a floor that separates adjoining dwelling houses, flats or rooms used for residential purposes. The Part E requirement for separating floors is subject to both airborne and impact sound regulations. Minimum airborne sound of 45dB is required (plus additional Ctr correction factor for low frequency noise). In addition separating floors also require a maximum 62dB impact sound insulation. Rockfloor will assist in achieving this performance requirement.

Flanking sound
A major cause of reduced acoustic performance in
separating floors is due to Flanking paths via the surrounding structure rather than a direct path through the floor.

Good practice detailing at the design stage, especially at key junctions, together with good workmanship will minimise this
effect and optimise performance levels. Guidelines of good practice detailing at key junctions are provided throughout the new Approved document E.


Exposed Intermediate Floors are by definition suspended and are only required to incorporate thermal insulation if the floor divides a heated space from an unheated space or outside air.
 
Rockwool Flexi  or RW5 rigid slabs are designed to provide the maximum thermal benefits for exposed  intermediate floors  and soffits.

The maximum allowable Elemental U values for exposed soffits are; (W/m2K)
. England, Wales 0.25
. Scotland 0.25
. Republic of Ireland 0.25


Exposed Intermediate Floors
Perform your own U-value calculations and Condensation Risk Analysis with BuildDesk U the free downloadable software from BuildDesk. For U-value training courses and consultancy visit the BuildDesk website to find out more.

Fire
Rockwool FirePro range offers fire prevention solutions for internal floors specifically for perimeter linear joints, and service penetration seals. 
SOLUTIONS BY CONSTRUCTION TYPES
Building
elements
Construction
guides
PerformanceNBS Plus
clause
CAD
downloads

Rockfloor

Separating floors,
concrete/
beam & block
- new build
Method

Movie

Acoustic
E1-(65mm sand & cement screed)
Airborne:
DnTw+Ctr=57dB

Impact: 43dB LnTw

(40mm proprietary screed)
Airborne:
DnTw+Ctr=61dB

Impact:45dB LnTw


Fire resistance   min. 60min
M10-290
M13-260


DXF 
  DWG   DWF


  
Separating floors,
timber - 
new build
Method

Movie

Acoustic
E1-Airborne:
Rw 54 dB
Impact: 
Lnw 62dB

Fire resistance  min. 60min

K11-215
K11-225
K11-235
K11-245


DXF   DWG   DWF


  
Separating floors,
metal - new build
Method

Movie

AcousticK11-215
K11-225
K11-235
K11-245


DXF   DWG   DWF


  
Rockwool Flexi

Failed to get HTML type: 516 id:95316.Inspect errorstack.
Separating floors,
timber - 
new build
Method

Movie

Acoustic
E1-Airborne:
Rw 54 dB
Impact: 
Lnw 62dB

Fire resistance  min. 60min

K11-215
K11-225
K11-235
K11-245


DXF   DWG   DWF


  
Separating floors,
metal - new build
Method

Movie

AcousticK11-215
K11-225
K11-235
K11-245


DXF   DWG   DWF


  
Intermediate
timber floors
Method

Movie

Acoustic
E2- Rw 40dB
P10-240
Isometric view
DXF   DWG   DWF

Side view

DXF   DWG   DWF

Exposed intermediate
floor soffits,
concrete deck
Method Acoustic,
thermal,
fire
K10-215
K10-225
K10-235

DXF   DWG   DWF

Slimfloor

Internal &
separating floors,
above concrete slab
- new build
Method

Movie

Acoustic
Robust details-
E-FC-1

E4-Airborne:
Rw 55dB
Impact:
55dB L
nw


K11-275
K11-295

DXF   DWG   DWF

  
RW5 rigid slab - tissue faced

Exposed intermediate
floor soffits,
concrete deck
Method Thermal, acoustic,
fire

U value req. is 0.25W/m2K. Use 150mm concrete floor slab, with 130mm thick RW5 .
K10-215
K10-225
K10-235

DXF
   DWG   DWF

  

Download free DWG from Autodesk & Adobe Reader

     Free DWG from Autodesk

 