| SEPARATING & INTERNAL FLOOR SOLUTIONS |
 When insulating internal floors, it is important to ensure that the building meets with the appropriate Building Regulation requirements. By adopting the Rockwool SoundPro solutions specifiers can meet and exceed the required ADE standards for Internal floors. Intermediate Floors (within the same dwelling)
The Approved Document E 2003 Edition – Resistance to the passage of sound, introduced standards for internal floors in dwelling houses, flats and rooms for residential purposes. By adopting the Rockwool SoundPro solutions you can meet and exceed the required ADE standards for Internal and Separating floors. The new Approved Document E (2003 edition) introduces, for the first time, performance criteria for Internal floors within the same building and dwelling (E2).This is based on laboratory rating (Rw) for which a minimum value for airborne sound insulation of Rw 40dB is required. Installing Rockwool Flexi slab between timber or metal floor joists can meet this performance requirement. |
|
Separating Floors Concrete Rockfloor (Acoustic)
Slimfloor (Acoustic)
Rockwool Flexi + Rockfloor (Acoustic)
Timber joists Rockwool Flexi + Rockfloor (Acoustic)
Metal joists Rockwool Flexi + Rockfloor (Acoustic)
Intermediate Floors Timber & metal joists Rockwool Flexi (Acoustic)
Exposed Intermediate Floors/Soffits Concrete Rigid slab RW5-tissue faced (Thermal, Acoustic, Fire)
Rockwool Flexi (Thermal, Acoustic, Fire) |
A Separating floor is defined as a floor that separates adjoining dwelling houses, flats or rooms used for residential purposes. The Part E requirement for separating floors is subject to both airborne and impact sound regulations. Minimum airborne sound of 45dB is required (plus additional Ctr correction factor for low frequency noise). In addition separating floors also require a maximum 62dB impact sound insulation. Rockfloor will assist in achieving this performance requirement.
Flanking sound A major cause of reduced acoustic performance in separating floors is due to Flanking paths via the surrounding structure rather than a direct path through the floor.
Good practice detailing at the design stage, especially at key junctions, together with good workmanship will minimise this effect and optimise performance levels. Guidelines of good practice detailing at key junctions are provided throughout the new Approved document E.
|
Exposed Intermediate Floors are by definition suspended and are only required to incorporate thermal insulation if the floor divides a heated space from an unheated space or outside air. Rockwool Flexi or RW5 rigid slabs are designed to provide the maximum thermal benefits for exposed intermediate floors and soffits.
The maximum allowable Elemental U values for exposed soffits are; (W/m2K) . England, Wales 0.25 . Scotland 0.25 . Republic of Ireland 0.25 |
 |
Perform your own U-value calculations and Condensation Risk Analysis with BuildDesk U the free downloadable software from BuildDesk. For U-value training courses and consultancy visit the BuildDesk website to find out more.
Fire Rockwool FirePro range offers fire prevention solutions for internal floors specifically for perimeter linear joints, and service penetration seals.
|
| SOLUTIONS BY CONSTRUCTION TYPES |
Building elements | Construction guides | Performance | NBS Plus clause | CAD downloads |
Separating floors, concrete/ beam & block - new build | Method
Movie
 | Acoustic E1-(65mm sand & cement screed) Airborne: DnTw+Ctr=57dB
Impact: 43dB LnTw
(40mm proprietary screed) Airborne: DnTw+Ctr=61dB
Impact:45dB LnTw
Fire resistance min. 60min | M10-290 M13-260
| DXF DWG DWF
| |
Separating floors, timber - new build | Method
Movie
 | Acoustic E1-Airborne: Rw 54 dB Impact: Lnw 62dB
Fire resistance min. 60min
| K11-215 K11-225 K11-235 K11-245 | DXF DWG DWF
| |
Separating floors, metal - new build | Method
Movie
| Acoustic | K11-215 K11-225 K11-235 K11-245 | DXF DWG DWF
| |
Failed to get HTML type: 516 id:95316.Inspect errorstack.
Separating floors, timber - new build | Method
Movie
 | Acoustic E1-Airborne: Rw 54 dB Impact: Lnw 62dB
Fire resistance min. 60min
| K11-215 K11-225 K11-235 K11-245 | DXF DWG DWF
| |
Separating floors, metal - new build | Method
Movie
| Acoustic | K11-215 K11-225 K11-235 K11-245 | DXF DWG DWF
| |
Exposed intermediate floor soffits, concrete deck | Method | Acoustic, thermal, fire | K10-215 K10-225 K10-235 | DXF DWG DWF | |
Internal & separating floors, above concrete slab - new build | Method
Movie
 | Acoustic Robust details- E-FC-1
E4-Airborne: Rw 55dB Impact: 55dB Lnw
| K11-275 K11-295 | DXF DWG DWF | |
Exposed intermediate floor soffits, concrete deck | Method | Thermal, acoustic, fire
U value req. is 0.25W/m2K. Use 150mm concrete floor slab, with 130mm thick RW5 . | K10-215 K10-225 K10-235 | DXF DWG DWF | |
Download free DWG from Autodesk & Adobe Reader
 |
|
|