| Installing Rockwool Flexi & Rockfloor |
Soundpro solution - Timber platform floor
E4 Schools: Airborne:Rw 59 dB Impact: 57 Lnw dB
Test Report ref. BTC 12397A
E1 Material change of use: Airborne: Rw 48 dB (Rw 59 - 11 Ctr)
Impact: Lnw 57 dB
Laboratory test Report ref. BTC 12397A Airborne: Rw 48 dB DnTw + Ctr
Impact: 58 dB LnTw
Site test Report no. 2271
|
 |
Rockwool SoundPro guidance specification
. 18mm t&g flooring grade chipboard spot bonded on . 15mm Lafarge dBcheck wallboard on (total mass 28Kg/m2) . 30mm min Rockwool Rockfloor resilient layer on . 15mm OSB floor deck on . 195 x 45mm timber joists @ 450mm ctrs . 100mm Rockwool Flexi between joists . Resilient bars fixed at right angles to joists @ 400mm ctrs. . Ceiling finish, 2 layers of 15mm Lafarge dBcheck wallboard (26 Kg/m2)
Points to note: If the existing ceiling is being replaced, the sound performance of the floor can be further enhanced by fitting resilient bars which isolate the ceiling from the floor structure.
. The floating platform floor should be isolated from the perimeter walls . Do not bridge between the floating layer and the base floor with services and fixings that penetrate the resilient layer . Leave min. 5 mm gap between the floating layer and skirtings. Seal gap with Rockwool Acoustic Sealant . Ensure all ceiling perimeters are sealed with tape or Rockwool Acoustic Sealant
|
|
|
| Back
| |
|
| |
|
Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |
|
Copyright © Rockwool Limited, Disclaimer |
|
|
|