Rockwool Flexi - U Values W/m2K
Cold pitched roof, attic extension/refurbishment- between rafters only
Prescribed U Value W/m2K
(England and Wales) Extensions, Renovation & Repair work: 0.20 New build requirement could range between 0.16 and 0.14
(Republic of Ireland) 0.20
(Scotland, with boiler SEDBUK) 0.20
| Rafter width
Joist spacing
Timber bridging
RW Flexi
Thickness mm | 38
400mm
9.5 %
| 38 600mm
6.3%
| 47
400mm
11.7%
| 47
600mm
7.8% | 200 (100+100 | 0.22 | 0.21 | 0.23 | 0.22 |
220 (100+120) | 0.21 | 0.20 | 0.21 | 0.20 | 240 (100+140) | 0.19 | 0.18 | 0.20 | 0.19 |
Construction: Tiles/slates on 25mm counter battens on BBA approved roof breather membrane, Rockwool Flexi fitted between rafters. An airtight vapour control membrane is stapled to the underside of the rafters, with joints lapped and sealed. Ceiling finished internally with 12.5mm plasterboard.
| |
|
|