Rockwool Flexi - U Values W/m2K

Cold pitched roof, attic extension/refurbishment- between rafters only

Prescribed U Value W/m2K

(England and Wales)
Extensions, Renovation & Repair work: 0.20
New build requirement could range between 0.16 and 0.14

(Republic of Ireland) 0.20

(Scotland, with boiler SEDBUK) 0.20


 

Rafter width

Joist spacing

Timber bridging


RW Flexi

Thickness mm              
38 

400mm  

9.5 % 
38 
 
600mm

6.3%

47

400mm 

11.7% 

47 

600mm

7.8%

200 (100+100

0.22

  0.21   

0.23

 0.22

220 (100+120)

   0.21   

0.20 

0.21

 0.20

240 (100+140)

   0.19   

0.18 

0.20

 0.19



Construction: Tiles/slates on 25mm counter battens on BBA approved roof breather membrane, Rockwool Flexi fitted between rafters. An airtight vapour control membrane is stapled to the underside of the rafters, with joints lapped and sealed. Ceiling finished internally with 12.5mm plasterboard.


 