| Rockwool Flexi specification |
Separating Walls – Timber frame
To meet minimum required performance standard: Airborne Sound DnTw + Ctr=43 dB (or greater)
ADE Construction guidance specifications for Wall Treatment 1: Existing solid masonry wall with independent panel(s)
|
. 100mm (min) existing solid masonry wall plastered on both faces
. Independent timber or steel studs. Min 10mm gap to be maintained between frame & existing wall
. 50mm Rockwool Flexi between studs (ADE requires min 35mm)
. 2 layers of plasterboard min 20Kg/m2 (approx=to 2x15mm std wallboard or 2 x 12.5mm E-check plasterboards)
. Avoiding flanking transmission: seal perimeter edges of new plasterboard with tape or Rockwool Acoustic Sealant
. If existing masonry wall is not plastered or less than 100mm thick then independent panels should be applied to both sides
. Pre-completion site testing is required
|
 |
|
|
| Back
| |
|
| |
|
Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |
|
Copyright © Rockwool Limited, Disclaimer |
|
|
|