Rockwool Ltd > Acoustic > SoundPro > Flanking > Ceiling voids - flanking


House Insulation
Technical Centre
Coated batt section
Environment
Rockwool UK


new service information section


Home

Careers

Contact

News



Add to My Favorites  MY FAVORITES







Flanking at ceiling voids

For ceiling voids greater than 1m
Total Room to Room Attenuation=Rw 50 dB
Test Report ref. SE89-0124

. 2 x 50mm thick Rockwool ‘foil faced’ Fire barrier provides 90 minutes fire integrity and insulation
. Rockfon Suspended Ceiling providing min Rw 30 dB room to room attenuation.









For ceiling voids up to a max of 1m
Total Room to Room Attenuation=Rw 50 dB

. 100mm thick Rockwool ‘foil faced’ Fire Barrier Slab provides 240 minutes fire integrity and 60 minutes insulation

. Rockfon Suspended Ceiling providing min Rw 30 dB room to room attenuation.








 Room to room attenuation Rw dB
 Typical lay-in grid system

 30

 Two thickness of 50mm Rockwool Fire Barrier –
 both foil faced

 50

 Rockwool Fire Barrier slab foil faced on both sides

 50


 

| Back |

| Top |
 

Rockwool Limited, Pencoed, Bridgend, CF35 6NY, UK
| 01656 862621 |     |
Copyright © Rockwool Limited, Disclaimer