This site uses javascript, some functionality and content is not working if javascript is disabled

Work on existing buildings - dwellings L1B & non dwellings L2B

Elemental U value used for extensions and refurbishment:

 

Dwellings and non-dwellings

Exposed element 

 Building fabric
 U value standards
Extensions*
L1B & L2B


W/m2K

Building fabric
U value standards
Renovation &
Repair work**
L1B & L2B

W/m2

 Pitched Roof
 Ceiling level
 Rafter line

0.16
0.20

0.16
0.20

 Flat Roof

0.20

0.25

 Walls

0.30

0.35 

 Floors

0.22

0.25

 Windows, doors      

1.80

2.00

Notes:
* For extension work to buildings other than dwellings L2B: Where the proposed extension has a total floor area greater than 100m2 and greater than 25% of the floor area of the existing building, it should be regarded as a new building and must comply with L2A using SBEM methodology.
* * Where more than 25% of the surface area is being renovated, then the whole element should be upgraded to meet the thermal performance shown in Table above. 

 
rockwool.co.uk Home