Domestic

To use the Elemental method, individual exposed building elements and other elements forming the insulation envelope of a dwelling or a building consisting of dwellings should have a U value which do not exceed the value given in the table below.

There are two levels of U value; Column A and column B. Column selection depends on the type of heating system to be installed in a dwelling and whether or not it has a central heating boiler with a SEDBUK of at least the percentages given in the table below.

Maximum U values for building elements using the Elemental method:

 

Exposed element

With boiler min. SEDBUK % ( see table below)
W/m2K

Other heating system
W/m2K

 Pitched Roof:

              insulated between rafters
              insulated between joists

 

0.20
0.16


 
0.18
0.16

 Flat roof or roof (including pitched) with integral insulation

 0.25

0.22

 Exposed wall, external wall

 0.30

0.27

 Exposed floor or floor

 0.25

0.22

 Windows, doors and rooflights:

               metal frames (area weighted average)
               wood on PVC frames (area weighted average)

 

2.20
2.00


 
2.00
1.80

Domestic - with boiler SEDBUK

Domestic - with boiler SEDBUK


Minimum boiler SEDBUK which allows U values in Column A of the above table to be used:

Central heating system fuel and boiler type 

 Minimum SEDBUK (%)

 Mains natural gas (all boiler types)

 78

 LPG (all boiler types)

 80

 Oil (combination boilers)

 82

 Oil (all other types of boilers)

 85

 Domestic - more demanding, other heating systems